Products
Sales Reps
Distributors
Woertz News
Product Releases
GBU Electrotech website
Tech. File
-
Cross reference
-
Terminal block drawings
-
Power supply drawings
Value-added services
ATEX
Comat
Products
Citel Products
Reign Power Supplies
Inventory
Close out
 
 
| |
|
Multibus 4 x 1.5
mm² (4 x 16 AWG) |
- Installation system for wiring bus and other
controlling systems which require 3 or 4 non twisted conductors
- Degree of protection IP42, higher degrees on
request
- Shutting down the connector allows the pointed
contacts to connect all conductors in one operation
- The installations are safe, secure and also
flexible
- Time and cost savings
- Easy extension of the installations
- Highly reduced fire load
|
|
|
Technical data concerning the flat
cable: |
 |
|
Conductors |
4 x 1.5 mm² |
|
Insulation of the leads |
thermoplastic PE, halogen-free |
|
Color of the leads |
black, red, white, brown |
|
Test voltage |
4kV |
|
Rated voltage |
300 V |
|
Current-carrying capacity |
24 A / conductor 90°C |
|
DC resistance |
13,3 Ohm/km |
|
Weight |
125 g/m |
|
Fire load |
7,137 kWh/m |
|
|
|
|
Art. No. |
49651 |
| |
|
Technical data concerning the
junction box |
 |
- For the junction between flat and round cable
- Connection by means of pointed contacts without
stripping off the insulation
- With 2 outputs for round cable 4 x 0.75 mm², Art.
No. 49665 (see below)
- Contacts at the output side designed for cable
Art. No. 49665
- Delivered with a stopper
|
|
Rated voltage |
48 V |
|
Rated current max. |
3,5 A |
|
Plastic parts |
halogen-free |
|
Metal parts |
resistant against corrosion |
|
Art. No. |
49670 |
| |
|
Technical data concerning the round
cable (output cable) |
 |
|
|
Conductors |
4 x 0.75 mm² |
|
Insulation of the leads |
black |
| Colour
of the leads |
black,
red, 2x white |
| |
|
|
Art. No. |
49665 |
 |
1. Position the base
plate of the junction box and screw it on the support if
necessary |
 |
2. Correctly insert the
multibus flat cable |
 |
3. Cut the desired length of
round cable, strip off the sheath and place it into the adaptor
(stripping off the insulation is not necessary) |
 |
4. Shut down the cover in
locked position |
 |
5. Fasten the cover with the
screws |
 |
6. Put the complete upper part
on the base plate in locked position |
 |
7. Shut down the upper part |
 |
8. And fasten it by means of
the screws |
|
Mounting procedure in a different order is also possible
(steps 1, 2, 6, 7, 8, 3, 4, 5). Wiring is then the last step of the
procedure. |
|